Junction function
Vertical GS MW U expansion joint = identical principles as in S/CH (page 22). Requires custom expansion flashing + loosely packed mineral wool.
Critical installation aspects
- Expansion flashing fixed on one side only to the “fixed” structure.
- No rigid fasteners within a 50 cm zone from the expansion joint.
- Loosely packed mineral wool — flexible under ±20 mm amplitude.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 51 — Expansion joint, vertical GS MW U layout. Scale 1:5.
Components in this junction
Panel (1)
- 01
Insulation (1)
- 05 Thermal insulation installed on site
Flashing (2)
- 03 Custom expansion flashing
- 04 OB-17 cover flashing (OB-17)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (1)
- 06 PES sealing tape
Element (1)
- 02 Steel column and rails per structural design