Detail · GS MW

Structural expansion joint — vertical GS MW U panel layout

Building structural expansion joint in a hall with vertical GS MW U panels. Identical logic as in S/CH (page 24) — custom expansion flashing absorbing ±20 mm movement, OB-17 cover flashing, mineral wool loosely packed.

Structural expansion joint — vertical GS MW U panel layout

Junction function

Vertical GS MW U expansion joint = identical principles as in S/CH (page 22). Requires custom expansion flashing + loosely packed mineral wool.

Critical installation aspects

  • Expansion flashing fixed on one side only to the “fixed” structure.
  • No rigid fasteners within a 50 cm zone from the expansion joint.
  • Loosely packed mineral wool — flexible under ±20 mm amplitude.

Documentation

Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 51 — Expansion joint, vertical GS MW U layout. Scale 1:5.

Components in this junction

Panel (1)
Insulation (1)
  • 05
    Thermal insulation installed on site
Flashing (2)
Fastener (2)
  • 07
    Self-drilling fastener for sandwich panels
  • 08
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (1)
  • 06
    PES sealing tape
Element (1)
  • 02
    Steel column and rails per structural design