Junction function
Floor — horizontal GS MW U = analogous to S/CH (page 29). Only for indoor halls or floors raised >15 cm above ground level.
Critical installation aspects
- Floor waterproofing required beneath the panel.
- On-site insulation with mineral wool at the column.
- Not recommended for unenclosed halls — no drip edge.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 59 — Floor, horizontal layout GS MW U. Scale 1:5.
Components in this junction
Panel (1)
- 01
Insulation (1)
- 06 On-site thermal insulation
Flashing (2)
- 03 Internal corner flashing OB-06 (OB-06)
- 04 Cover flashing for panel joints
Fastener (3)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
- 09 Steel quick-mount expansion anchor
Sealant (1)
- 05 PES sealing tape
Element (1)
- 02 Steel column as per structural design