Junction function
Horizontal GS MW U plinth = variant with the OB-41 angle (specific to horizontal U, not used in S/CH). Vs horizontal S/CH (pp. 29-30):
- OB-41 angle instead of OB-38/OB-42 — the U joint geometry requires a different guide.
- Internal OB-07 instead of OB-06 (horizontal S/CH used OB-06).
- PM1 washers in panel fixing.
Critical installation aspects
- OB-41 angle anchored with expansion anchors to the sill beam; PM1 at each fastener.
- Internal OB-07 — full finishing of the inner edge.
- PURS assembly foam under the panel — eliminates capillary moisture rise.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 56 — Plinth, horizontal GS MW U layout, variant I. Scale 1:5.
Components in this junction
Panel (1)
- 01
Flashing (2)
- 03 OB-41 starting angle (OB-41)
- 04 OB-07 internal corner flashing (OB-07)
Accessory (1)
- 08 PM1 fixing washer (PM1)
Fastener (3)
- 07 Self-drilling fastener for sandwich panels
- 09 Steel quick-fix expansion anchor
- 10 Self-drilling fastener for sheet metal or rivet 4.0×8.0
Sealant (2)
- 05 PES sealing tape
- 06 Impregnated PURS gasket or assembly foam
Element (1)
- 02 Structural elements + insulation