Junction function
Variant II of the horizontal U plinth = greater overhang d=60-100 mm + OB-39 Z-profile (instead of the OB-41 angle from variant I). Suitable for tall, premium facades.
Critical installation aspects
- OB-39 Z-profile = profiled “Z”-shaped sheet metal; stiffer than an angle, better at handling large overhangs.
- OB-06 internal flashing instead of OB-07 (minor geometric difference for the larger overhang).
- Drainage strip in the ground below the drip edge.
- Strength check after the first season — verify Z-profile stiffness under wind load.
Documentation
GS MW S/CH/U Technical Catalogue (Gór-Stal 2025), page 57 — Plinth, horizontal GS MW U layout, variant II. Scale 1:5.
Components in this junction
Panel (1)
- 01
Flashing (2)
- 03 OB-39 starting Z-profile (OB-39)
- 04 OB-06 internal corner flashing (OB-06)
Accessory (1)
- 08 PM1 mounting washer (PM1)
Fastener (3)
- 07 Self-drilling fastener for sandwich panels
- 09 Steel quick-mount expansion anchor
- 10 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (2)
- 05 PES sealing tape
- 06 Impregnated PURS gasket or installation foam
Element (1)
- 02 Structural elements + insulation