Junction function
Horizontal GS MW U wall junction = identical to horizontal S/CH (page 32) with replacement of OB-19 cover flashing → OB-18 (minor geometric difference).
Critical installation aspects
- Class A1 mineral wool for fire-resistant walls.
- Wall waterproofing continued behind OB-18.
- PM1 in the edge zone instead of standard fasteners.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 62 — Wall junction, horizontal GS MW U layout. Scale 1:5.
Components in this junction
Panel (1)
- 01
Insulation (1)
- 06 Mineral wool
Flashing (2)
- 03 OB-18 cover flashing (OB-18)
- 04 OB-07 internal corner flashing (OB-07)
Accessory (1)
- 08 PM1 fixing washer (PM1)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 09 Self-drilling fastener for sheet metal or rivet 4.0×8.0
Sealant (1)
- 05 PES sealing tape
Element (1)
- 02 Wall and column per structural design