Junction function
Window GS MW U vertical, vertical section = identical principles as in S/CH (p. 25). Only OB-13 above the window (without OB-10 from S/CH) — minimalist premium aesthetics.
Critical installation aspects
- OB-13 drip edge with 30 mm drip nose.
- OB-37 window sill with 5% slope.
- OB-16 stiffener — sill acoustics.
- Neutral silicone + low-expansion foam around the window.
- Edge zone around the window — densified PM1 + fasteners.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 54 — Window, vertical GS MW U layout, vertical section. Scale 1:5.
Components in this junction
Panel (1)
- 01
Flashing (4)
- 04 OB-13 drip edge (OB-13)
- 05 OB-37 window sill (OB-37)
- 06 OB-16 stiffening flashing (OB-16)
- 07 Custom internal corner
Fastener (3)
- 09 Self-drilling fastener for sandwich panels
- 10 Self-drilling fastener for sheet metal or rivet 4.0×8.0
- 11 Standard one-sided rivet 4.8×15.1 to structure
Sealant (2)
- 08 PES sealing tape
- 12 Neutral silicone sealant
Element (2)
- 02 Sub-framing per structural design
- 03 PVC / aluminium window with fixing connectors