Junction function
Cold room door installed in GS insPIRe® CH wall for chambers at temperatures > 0°C (typically +2°C to +8°C — storage of fresh food, pharmaceuticals, fruit).
Critical detail element: the PVC rod-nut fixing system (items 03-05) eliminates the thermal bridge typical of direct steel frame fixing to the panel:
- Ø10 steel rod (item 05) passes through the panel with PVC insulation (item 03) on both sides.
- The steel nut (item 06) does not contact the panel — the load is transferred by the PVC nut (item 03).
- No metal penetrates the full insulation thickness → no water vapour condensation on the nut on the warm side.
Critical installation aspects
- Ø10 threaded rod (item 05) — galvanised, length = panel thickness + 40 mm (margin for PVC + steel nuts).
- PVC insulating nut (item 03) — internal steel insert carries the load, external PVC provides thermal insulation.
- PVC washer (item 04) between panel and steel nut — eliminates point crushing of the panel.
- Threshold (bottom junction) — door rests on the concrete floor (item 08); bottom frame fixed to the floor with chemical anchors.
- Plastic sealing compound (item 09) along the perimeter of the frame on both sides — fills minor irregularities, eliminates air leakage.
- Closing flashing (item 07) covers the frame-panel joint, fixed with fasteners and washers (item 10) every 200 mm.
Chilled vs frozen storage
| Aspect | Cold room (this junction, t > 0°C) | Freezer (t < 0°C) — see |
|---|---|---|
| Fixing system | PVC rod-nut (same) | PVC rod-nut (same) |
| Floor | concrete + resin flooring | concrete + PIR insulation + underfloor heating |
| Condensation risk | moderate (condensation on warm side) | high (condensation + freezing) |
| Door gasket | standard EPDM | frost-resistant EPDM down to -40°C |
Used in the GS insPIRe® CH cold room wall system.
Documentation
Gór-Stal Cold Storage Catalogue 2025, p. 21 — cold room door, vertical section.
Components in this junction
Panel (1)
- 01 GS insPIRe® CH / CH MAX cold room panel (insPIRe CH)
Flashing (1)
- 07 Closing flashing
Accessory (2)
- 03 PVC insulating nut with steel insert
- 04 PVC mounting washer
Fastener (3)
- 05 Galvanised steel threaded rod Ø10
- 06 Steel nut M10 with washer Ø21/Ø10.5
- 10 Self-drilling fastener for sheet metal or rivet 4.0 × 8.0
Sealant (1)
- 09 Permanently plastic sealing compound
Element (2)
- 02 Cold room door
- 08 Floor as per architectural design