Detail · insPIRe®

Concrete support — horizontal insPIRe® U panel layout

Premium fixing of horizontal PIR panels to RC column. Chemical or mechanical anchors, PM1 for U-lock, OB-17 cover flashing.

Concrete support — horizontal insPIRe® U panel layout

Junction function

RC column support U = analogous to MiWo U (p. 65).

Critical installation aspects

  • Chemical anchors (Hilti HVU, Fischer FIS).
  • Rebar scanner before drilling.
  • PM1 + anchor = concealed fixing in concrete.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 69 — RC column support, horizontal U layout. Scale 1:5.

Components in this junction

Panel (1)
Flashing (1)
Accessory (1)
Fastener (2)
  • 06
    Concrete fixing (chemical anchor)
  • 08
    Self-drilling sheet-metal fastener or 4.0×8.0 rivet
Sealant (2)
  • 04
    PES sealing tape
  • 05
    Impregnated PURS gasket or PU foam
Element (1)
  • 02
    RC column per structural design