Detail · insPIRe®

Edge support — horizontal insPIRe® U panel layout

Premium fixing of horizontal panels at the end column of the hall. OB-17 cover flashing + PM1 concealed fastening.

Edge support — horizontal insPIRe® U panel layout

Junction function

Edge support U = analogous to MiWo U (p. 66).

Critical installation aspects

  • 20 mm gap between panel and column.
  • PM1 + fastener in the joint.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 70 — Edge support, horizontal U layout. Scale 1:5.

Components in this junction

Panel (1)
Flashing (1)
Accessory (1)
Fastener (2)
Sealant (2)
Element (1)
  • 02
    Steel column per structural design