Junction function
Horizontal insPIRe® S expansion joint = analogous to MiWo S/CH (page 35). For buildings >60-80 m.
Critical installation aspects
- Expansion flashing fixed on one side only.
- 50 cm strip free of rigid fasteners.
- Insulation loosely packed — flexible under ±20 mm.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 34 — Expansion joint, horizontal S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Insulation (1)
- 05 Site-installed thermal insulation
Flashing (2)
- 03 Custom expansion flashing
- 04 OB-17 cover flashing (OB-17)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (1)
- 06 PES sealing tape
Element (1)
- 02 Steel column and rail framing per structural design