Junction function
Vertical insPIRe® S expansion joint = analogous to MiWo S/CH (p. 22). Required for buildings >60–80 m.
Critical installation aspects
- Expansion flashing fixed on one side only — to the “fixed” side.
- No rigid fasteners within a 50 cm zone from the expansion joint.
- On-site insulation with mineral wool or PIR foam.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 19 — Expansion joint, vertical S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Insulation (1)
- 05 Thermal insulation installed on site
Flashing (2)
- 03 Custom expansion flashing
- 04 OB-17 cover flashing (OB-17)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or rivet 4.0×8.0
Sealant (1)
- 06 PES sealing tape
Element (1)
- 02 Steel column and rail framing per structural design