Detail · insPIRe®

Structural expansion joint — vertical insPIRe® U panel layout

Expansion joint detail for halls with premium vertical PIR panels. Custom ±20 mm expansion flashing, OB-17 cover trim, on-site insulation.

Structural expansion joint — vertical insPIRe® U panel layout

Function of the junction

Vertical U expansion joint = analogous to S (p. 21). Required for buildings >60–80 m.

Critical installation aspects

  • One-sided fastening.
  • No rigid fasteners within 50 cm of the expansion joint.
  • Free-floating insulation.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 55 — Expansion joint, vertical U layout. Scale 1:5.

Components in this junction

Panel (1)
Insulation (1)
  • 05
    Thermal insulation installed on site
Flashing (2)
Fastener (2)
  • 07
    Self-drilling fastener for sandwich panels
  • 08
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (1)
  • 06
    PES sealing tape
Element (1)
  • 02
    Steel column and rail framing per structural design