Base · insPIRe®

Floor connection — horizontal insPIRe® S panel layout

Bottom edge of horizontally laid PIR panels on concrete floor (without base beam). OB-06 corner flashing finishes the edge, quick-fix expansion anchors secure the structure.

Floor connection — horizontal insPIRe® S panel layout

Junction function

Floor, horizontal insPIRe® S = analogous to MiWo S/CH (page 29). For internal halls / floors raised above ground level only.

Critical installation aspects

  • Floor waterproofing beneath the panel.
  • PURS foam seals the gap.
  • Expansion anchors every 60 cm.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 28 — Floor, horizontal S layout. Scale 1:5.

Components in this junction

Panel (1)
Flashing (2)
Fastener (3)
Sealant (2)
Element (1)
  • 02
    Steel column as per structural design