Base · insPIRe®

Floor base installation — horizontal layout of insPIRe® U panels

Premium horizontal PIR panels fixed to concrete floor without sill beam. OB-06 finishes the bottom edge, quick-mount expansion anchors.

Floor base installation — horizontal layout of insPIRe® U panels

Junction function

Floor U horizontal = analogous to S (page 30). For internal halls only.

Critical installation aspects

  • Waterproofing beneath the panel.
  • Not recommended for unheated halls.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 65 — Floor, horizontal U layout. Scale 1:5.

Components in this junction

Panel (1)
Insulation (1)
  • 06
    On-site thermal insulation
Flashing (2)
Fastener (3)
  • 07
    Self-drilling fastener for sandwich panels
  • 08
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
  • 09
    Steel quick-mount expansion anchor
Sealant (1)
  • 05
    PES sealing tape
Element (1)
  • 02
    Steel column per structural design