Junction function
Vertical GS MW U floor = direct fixing to floor without base beam; construction identical to S/CH (page 18), but with U panel featuring concealed fixing.
Critical installation aspects
- OB-42 channel raised 30 mm above floor level (waterproofing).
- Expansion anchors every 60 cm in the central zone, 40 cm in the edge zone.
- Mineral wool inside the channel — acoustics + EI 30.
- System water resistance — without drip flashing only for internal halls or floors elevated above ground level.
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 47 — Floor mounting, vertical U layout. Scale 1:5.
Components in this junction
Panel (1)
- 01
Insulation (1)
- 04 Rock mineral wool infill
Flashing (2)
- 02 OB-42 starting channel (OB-42)
- 03 OB-05 trim flashing (OB-05)
Fastener (3)
- 05 Self-drilling fastener for sandwich panels
- 06 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
- 07 Steel quick-mount expansion anchor