Junction function
Variant II of the flush edge = with an additional raised fastener. For aggressive wind conditions (zones III/IV per PN-EN 1991-1-4).
Critical installation aspects
- Additional raised fastener = better anchoring of the building outline.
- Other rules = as in variant I (page 97).
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 96 — Flush edge, variant II. Scale 1:5.
Components in this junction
Panel (2)
- 01 GS PIR D roof panel (GS PIR D)
- 03 GS insPIRe® U wall panel (insPIRe U)
Flashing (2)
- 04 Custom masking flashing
- 05 Internal corner flashing OB-02 (OB-02)
Accessory (1)
- 09 PM1 mounting washer (PM1)
Fastener (3)
- 08 Self-drilling fastener for sandwich panels
- 10 Self-drilling fastener for metal sheets (hex head)
- 11 Self-drilling fastener for metal sheets (washer head)
Sealant (2)
- 06 PES sealing tape
- 07 Polyurethane assembly foam
Element (1)
- 02 Building structure per design