Junction function
Flush edge = roof without projecting eaves — roof edge = wall edge. Used in modern offices next to halls, car showrooms, eco-buildings.
Variant I = standard custom concealment flashing (i.e. individually designed but typical).
Critical installation aspects
- No projecting eaves = water runs directly down the façade → enhanced wall protection required.
- Custom flashing compatible with roof + wall geometry.
- Internal OB-02 conceals the joint on the inside.
- Integral gutter or water drainage via roof drains (typically 2–3 per 100 m² of roof).
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 95 — Flush edge, variant I. Scale 1:5.
Components in this junction
Panel (2)
- 01 GS PIR D roof panel (GS PIR D)
- 03 GS insPIRe® U wall panel (insPIRe U)
Flashing (2)
- 04 Custom concealment flashing
- 05 Internal corner flashing OB-02 (OB-02)
Accessory (1)
- 09 PM1 fastening washer (PM1)
Fastener (3)
- 08 Self-drilling fastener for sandwich panels
- 10 Self-drilling fastener for sheet metal (hex head)
- 11 Self-drilling fastener for sheet metal (washer head)
Sealant (2)
- 06 PES sealing tape
- 07 Polyurethane installation foam
Element (1)
- 02 Building structure per project