Gate opening · insPIRe®

Gate lintel — horizontal U sandwich panel layout (concealed fixing)

Gate lintel set into a wall of insPIRe® U panels laid horizontally. Panels continue at the sides of the gate + concealed joint = the most minimalist geometry around a gate in our portfolio.

Gate lintel — horizontal U sandwich panel layout (concealed fixing)

Junction function

Gate lintel in a horizontal layout with concealed U fixing — a combination of two optimisations:

  1. Horizontal layout — panels continue at the sides of the gate (fewer cut edges vs vertical layout).
  2. Concealed U fixing — fasteners invisible from the outside, smooth facade, premium aesthetics.

This is the solution for car showrooms, premium warehouses and retail buildings with low roofs where the facade is part of the marketing (project photos in the client’s brochures).

Critical installation aspects

  • Steel lintel beam (item 03) — designed for gate weight + weight of the panel strip above the gate. Typically IPE 180-240 for gates 4-6 m wide.
  • Panels above the lintel fixed to the lintel beam + upper structure, with double fastener density in the 30 cm strip from the beam. Fasteners concealed in the U joint.
  • OB-20 lintel flashing (item 04) across the full opening width, OB-21 side flashing (item 05) on each side.
  • OB-01 corner flashing at the 4 corners of the gate opening + PES gasket (item 07) between flashing and panel (the flat U surface → easier flashing contact than with S).
  • Panel strip below the lintel (between the beam and the floor at the gate sides) — continuation of horizontal panels. Edges cut at the gate finished with OB-21.
  • Roller box seated in the structural zone above the lintel beam.

Comparison of 4 gate lintel variants

VariantPanel layoutFixingAestheticsPrice
U horizontal (this one)horizontalconcealedpremium minimalist+30-35% vs S vertical
U verticalverticalconcealedpremium industrial+20%
S horizontalhorizontalvisibleeconomical retail-15% (panels) +0% (flashings)
S verticalverticalvisibletypical industrialbaseline

Occurs in the insPIRe® U concealed hall wall system.

Documentation

Gór-Stal Technical Catalogue 2025, p. 75 — gate lintel in horizontal layout, U panel.

Components in this junction

Panel (1)
Flashing (3)
Accessory (1)
Fastener (2)
  • 09
    Self-drilling fastener for sandwich panels (hidden in U joint)
  • 12
    Sheet metal fastener (washer head)
Sealant (3)
  • 07
    PES sealing tape
  • 08
    EPDM gate gasket
  • 13
    Neutral frost-resistant silicone
Element (3)
  • 02
    Building structure per design
  • 03
    Steel lintel beam
  • 11
    Gate roller box