Junction function
Gate post insPIRe® S vertical = analogous to MiWo S/CH (p. 23). OB-21 reinforced against forklift impact.
Critical installation aspects
- Reinforced OB-21 + optional bumper guard.
- EPDM between gate and OB-21 = airtightness.
- Gate post anchors independent, transferring wind load on the gate.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 20 — Gate post, vertical S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Insulation (1)
- 05 Thermal insulation fitted on site
Flashing (1)
- 04 OB-21 gate flashing (OB-21)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (1)
- 06 PES sealing tape
Element (2)
- 02 Steel column and rail framing per structural design
- 03 Industrial roller gate