Junction function
Intermediate support insPIRe® S = analogous to MiWo S/CH (p. 34). Panel runs continuously past the column.
Critical installation aspects
- Fixing every 60-80 cm along the column.
- Thermal bridge minimal — typically 0.01 W/K per fastener.
- OB-17 optional for halls with low aesthetic requirements.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 33 — Intermediate support, horizontal S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (1)
- 03 OB-17 trim flashing (OB-17)
Fastener (2)
- 05 Self-drilling fastener for sandwich panels
- 06 Self-drilling fastener for sheet metal or rivet 4.0×8.0
Sealant (1)
- 04 PES sealing tape
Element (1)
- 02 Steel column per structural design