Junction function
Variant II of the gable = OB-31 instead of OB-32 + overlap ≤350 mm. An aesthetic and structural alternative.
Critical installation aspects
- OB-31 is typically wider than OB-32; the overlap inherently controls dimensional accuracy.
- Other rules are identical to variant I (p. 93).
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 92 — Monopitch roof + wall, variant II. Scale 1:5.
Components in this junction
Panel (2)
- 01 GS PIR D roof panel (GS PIR D)
- 03 GS insPIRe® U wall panel (insPIRe U)
Flashing (3)
- 05 Profiled flashing OB-28 (OB-28)
- 06 Gable flashing OB-31 (OB-31)
- 07 Corner flashing OB-02 (OB-02)
Accessory (1)
- 11 PM1 mounting washer (PM1)
Fastener (3)
- 10 Self-drilling fastener for sandwich panels
- 12 Self-drilling fastener for sheet metal (hex head)
- 13 Self-drilling fastener for sheet metal (washer head)
Sealant (3)
- 04 Profiled PE gasket
- 08 PES sealing tape
- 09 Polyurethane installation foam
Element (1)
- 02 Building structure as per design