Base · insPIRe® CH / termPIR®

Freezer partition wall at floor — Variant II

Variant II with **PVC skirting** instead of the concrete plinth profile (variant I, p. 36). Less massive finish, better when heavy concrete structures are to be avoided.

Freezer partition wall at floor — Variant II

Junction function

Variant II of the freezer partition wall = with PVC skirting. Lighter construction, easier installation compared to variant I with the concrete plinth.

Critical installation aspects

  • PVC skirting seals the panel-to-floor joint.
  • termPIR under-floor insulation identical to variant I.
  • Stainless fastener with EPDM gasket.

Documentation

GS insPIRe® CH Cold-Store Catalogue (Gór-Stal 2025), page 33 — Freezer partition wall at floor, variant II. Scale 1:5.

Components in this junction

Panel (1)
Insulation (1)
  • 02
    termPIR® insulation board (termPIR)
Flashing (1)
  • 08
    PVC skirting
Fastener (1)
  • 09
    Stainless self-drilling fastener with gasket
Sealant (1)
  • 07
    Polyurethane assembly foam
Element (4)
  • 03
    Concrete floor slab
  • 04
    Cementitious levelling layer
  • 05
    Vapour barrier — bituminous felt or PE film
  • 06
    Concrete floor screed as per project