Junction function
Variant II of the horizontal plinth = with channel + two-piece OB-15+OB-15a drip flashing. Alternative solution to variant I; lighter aesthetics.
Critical installation aspects
- OB-15 + OB-15a installed in sequence: stiffening element anchored with expansion anchors, then drip flashing bonded onto the stiffener.
- OB-15/15a joints sealed with neutral silicone.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 27 — Plinth, horizontal S layout, variant II. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (3)
- 03 OB-42 starter channel (OB-42)
- 04 OB-15 drip flashing (OB-15)
- 05 OB-15a stiffening flashing (OB-15a)
Fastener (3)
- 08 Self-drilling fastener for sandwich panels
- 09 Steel quick-mount expansion anchor
- 10 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (3)
- 06 PES sealing tape
- 07 Impregnated PURS gasket or installation foam
- 11 Neutral silicone sealant
Element (1)
- 02 Structural elements + insulation