Base · insPIRe®

Plinth at sill beam — vertical layout of insPIRe® S panels, variant I

Standard plinth for vertical PIR layout. Variant I (d=20-60 mm) with OB-13 flashing + optional OB-10 + OB-08 internal cover trim. PES seals + PURS foam + silicone.

Plinth at sill beam — vertical layout of insPIRe® S panels, variant I

Junction function

Vertical insPIRe® S plinth = standard solution for typical halls with PIR (vs MW with mineral wool). Functionally identical to vertical MiWo S (p. 16 of the MiWo catalogue), but with a PIR core.

Variant I = overhang d=20-60 mm = standard.

Critical installation aspects

  • PURS installation foam (item 08) beneath the panel — eliminates capillary moisture rise.
  • PES tape (item 07) at the joint with the plinth profile.
  • OB-13 projects 20-60 mm beyond the façade with a 30 mm drip edge.
  • Neutral silicone (item 11) at sheet-metal joints.
  • PIR vs MW — PIR is thinner at the same U-value → less space required, lower structural load.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 12 — Plinth, vertical S layout, variant I. Scale 1:5.

Components in this junction

Panel (1)
Flashing (4)
Fastener (2)
  • 09
    Self-drilling fastener for sandwich panels
  • 10
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (3)
  • 07
    PES sealing tape
  • 08
    Impregnated PURS gasket or installation foam
  • 11
    Neutral silicone sealant
Element (1)
  • 03
    Sill beam with insulation and thermal protection