Base · insPIRe®

Plinth at sole plate — vertical insPIRe® U panel layout, variant I

Premium plinth with concealed PIR fixing. Variant I (d=20-60 mm) — minimalist drip flashing. PM1 + OB-13 + OB-09 cover trim (different geometry for U-joint).

Plinth at sole plate — vertical insPIRe® U panel layout, variant I

Junction function

Vertical insPIRe® U plinth = analogous to MiWo U (p. 49). Premium variant with concealed PIR fixing.

Critical installation aspects

  • PM1 anchors the panel to the sole plate.
  • OB-09 cover trim is wider than OB-08 (due to U-joint geometry).
  • Installation foam beneath the panel.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 48 — Plinth, vertical U layout, variant I. Scale 1:5.

Components in this junction

Panel (1)
Flashing (3)
Accessory (1)
Fastener (2)
  • 08
    Self-drilling fastener for sandwich panels
  • 10
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (2)
  • 06
    PES sealing tape
  • 07
    Impregnated polyurethane gasket
Element (1)
  • 03
    Sole plate with insulation