Junction function
RC column support insPIRe® S = analogous to MiWo S/CH (p. 36). Hybrid halls with reinforced concrete columns.
Critical installation aspects
- Chemical anchors (Hilti HVU, Fischer FIS) — concrete min. C20/25.
- Rebar scanner before drilling.
- PURS foam in the 20 mm gap.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 35 — RC column support, horizontal S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (1)
- 03 OB-17 cover flashing (OB-17)
Fastener (2)
- 06 Concrete fastener (anchor)
- 07 Self-drilling metal-to-metal fastener or 4.0×8.0 rivet
Sealant (2)
- 04 PES sealing tape
- 05 Impregnated PURS gasket or installation foam
Element (1)
- 02 RC column as per structural design