Junction function
Variant II of skylight along slope = alternative lateral flashing solution. Selection at designer’s discretion.
Critical installation aspects
- Custom flashing compatible with skylight geometry.
- Remaining rules = as in variant I (p. 106).
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 105 — Skylight along slope, variant II. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS PIR D roof panel (GS PIR D)
Flashing (1)
- 03 Custom cover flashing
Fastener (1)
- 06 Self-drilling fastener for sheet metal (hex head)
Sealant (3)
- 04 PES sealing tape
- 05 Polyurethane assembly foam
- 07 Butyl sealing compound
Element (1)
- 02 Skylight with upstand