Wall junction · insPIRe®

Wall junction — vertical insPIRe® S panel layout

Connection of vertical PIR panels to a structural wall (RC / brick). External OB-19 flashing + internal corner OB-07 + PURS expanding foam or sealing tape in the gap.

Wall junction — vertical insPIRe® S panel layout

Junction function

insPIRe® S to wall junction = analogous to MiWo S/CH (page 21), with PIR instead of mineral wool.

Critical installation aspects

  • PURS foam instead of mineral wool — PIR is rigid.
  • Wall waterproofing continued behind the OB-19 flashing.
  • Thermal movement — flexible foam fill + compensation gap.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 18 — Wall junction, vertical S layout. Scale 1:5.

Components in this junction

Panel (1)
Flashing (2)
Fastener (2)
Sealant (2)
Element (1)
  • 02
    Wall and framing per structural design