Junction function
insPIRe® S to wall junction = analogous to MiWo S/CH (page 21), with PIR instead of mineral wool.
Critical installation aspects
- PURS foam instead of mineral wool — PIR is rigid.
- Wall waterproofing continued behind the OB-19 flashing.
- Thermal movement — flexible foam fill + compensation gap.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 18 — Wall junction, vertical S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (2)
- 03 OB-19 flashing trim (OB-19)
- 04 OB-07 internal corner trim (OB-07)
Fastener (2)
- 07 Self-drilling fastener for sandwich panels
- 08 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (2)
- 05 PES sealing tape
- 06 Impregnated PURS gasket or expanding foam
Element (1)
- 02 Wall and framing per structural design