Junction function
Window in horizontal panel layout — horizontal section = top view, window side jamb. Analogous to the vertical layout (p. 26): custom flashings, corners, window frame fixing with rivets.
Critical installation aspects
- Custom side flashings ordered together with the flashing set for the entire building.
- 4 custom internal corners per window.
- Side window frame fixing — rivets every 60 cm.
- Neutral silicone + low-expansion foam around the perimeter.
- Side tolerance ±5 mm (greater than in vertical layout).
Documentation
Technical Catalogue GS MW S/CH/U (Gór-Stal 2025), page 38 — Window, horizontal layout, horizontal section. Scale 1:5.
Components in this junction
Panel (1)
- 01
Flashing (2)
- 04 Custom cover flashing (side)
- 05 Custom internal corner
Fastener (2)
- 07 Self-drilling sheet metal screw or rivet 4.0×8.0
- 08 Standard blind rivet 4.8×15.1 to structure
Sealant (1)
- 06 PES sealing tape
Element (2)
- 02 Sub-framing per structural design
- 03 PVC / aluminium window with fixing connectors