Junction function
Side jamb of variant II in horizontal layout = minimalist window construction.
Critical installation aspects
- Neutral silicone around the perimeter.
- Acceptable for halls with low aesthetic requirements.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 41 — Window, horizontal S layout, variant II, horizontal section. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Element (1)
- 02 PVC / aluminium window with mounting profile