Window opening · insPIRe®

Window — horizontal insPIRe® S panel layout, variant II, vertical section

Simplified window installation with mounting profile in horizontal PIR layout. Window profile directly on the panel, without additional side flashings. OB-11 drip edge optional.

Window — horizontal insPIRe® S panel layout, variant II, vertical section

Junction function

Window variant II in horizontal layout = simplified solution with mounting profile integrated into the window frame.

Critical installation aspects

  • Window profile compatible with panel thickness.
  • Neutral silicone around the perimeter.
  • OB-11 drip edge optional.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 40 — Window, horizontal S layout, variant II, vertical section. Scale 1:5.

Components in this junction

Panel (1)
Flashing (1)
Fastener (1)
  • 04
    Self-drilling sheet metal fastener or rivet 4.0×8.0
Sealant (1)
  • 05
    Neutral silicone sealant
Element (1)
  • 02
    PVC / aluminium window with mounting profile