Junction function
Window variant II in vertical layout = simplified installation with a mounting profile integrated into the window frame. No additional side flashings — the window profile abuts the panel directly.
Used for:
- Windows specifically designed for halls with sandwich panels (Schüco, Aluprof Eco type).
- Cost optimisation — fewer flashings, less labour.
Critical installation aspects
- The window profile must have a width compatible with the panel thickness; verify with the window manufacturer.
- Neutral silicone around the entire perimeter — crucial for airtightness.
- OB-11 drip flashing optional — for windows in elevated zones exposed to rain.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 24 — Window, vertical S layout, variant II, vertical section. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (1)
- 03 OB-11 drip flashing (optional) (OB-11)
Fastener (1)
- 04 Self-drilling sheet metal fastener or rivet 4.0×8.0
Sealant (1)
- 05 Neutral silicone sealant
Element (1)
- 02 PVC / aluminium window with mounting profile