Junction function
Window variant II in horizontal U layout = simplified with mounting profile.
Critical installation aspects
- Window profile compatible with U lock.
- Additional flashing at panel joint.
- Neutral silicone.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 76 — Window, horizontal U layout, variant II, vertical section. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® U wall panel (insPIRe U)
Flashing (2)
- 03 OB-11 drip flashing (optional) (OB-11)
- 04 Additional flashing at panel joint
Fastener (1)
- 05 Self-drilling sheet metal fastener or 4.0×8.0 rivet
Sealant (1)
- 06 Neutral silicone sealant
Element (1)
- 02 PVC / aluminium window with mounting profile