Window opening · insPIRe®

Window — horizontal insPIRe® U panel layout, variant II, vertical section

Simplified window installation with mounting profile in premium horizontal PIR layout. OB-11 drip flashing optional + additional flashing at panel joint.

Window — horizontal insPIRe® U panel layout, variant II, vertical section

Junction function

Window variant II in horizontal U layout = simplified with mounting profile.

Critical installation aspects

  • Window profile compatible with U lock.
  • Additional flashing at panel joint.
  • Neutral silicone.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 76 — Window, horizontal U layout, variant II, vertical section. Scale 1:5.

Components in this junction

Panel (1)
Flashing (2)
Fastener (1)
  • 05
    Self-drilling sheet metal fastener or 4.0×8.0 rivet
Sealant (1)
  • 06
    Neutral silicone sealant
Element (1)
  • 02
    PVC / aluminium window with mounting profile