Junction function
Window variant II in vertical U = simplified installation with mounting profile in premium PIR.
Critical installation aspects
- Window profile compatible with U panel thickness.
- Additional flashing at panel joint (difference vs S).
- Neutral silicone around the perimeter.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 60 — Window, vertical U layout, variant II, vertical section. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® U wall panel (insPIRe U)
Flashing (2)
- 03 OB-11 drip flashing (option) (OB-11)
- 04 Additional flashing at panel joint
Fastener (1)
- 05 Self-drilling sheet metal screw or 4.0×8.0 rivet
Sealant (1)
- 06 Neutral silicone sealant
Element (1)
- 02 PVC / aluminium window with mounting profile