Junction function
Eaves with gutter drainage is the most common detail in industrial halls and warehouses — a complete solution for rainwater drainage from a sandwich panel roof. Three functions in parallel:
- Water drainage — water running off the roof slope flows into the gutter via the OB-26 sub-gutter Z-flashing.
- Snow safety — the OB-27 barrier prevents snow avalanches at the eaves (fire-safety requirement for retail and office buildings with a walkway under the eaves).
- Panel edge finishing — the factory-trimmed roof edge (item 01) eliminates exposure of the PIR core.
Variant I vs II
| Aspect | Variant I (this one) | Variant II |
|---|---|---|
| Sub-gutter flashing | OB-26 Z-flashing | OB-25 C-channel |
| Drip edge | none separate | OB-33 additional |
| Compactness | higher (fewer elements) | lower (more flashings) |
| Eaves aesthetics | more “industrial” | more “finished” |
| Price per linear m | base | +15-20% |
Variant I is chosen for warehouse halls where aesthetics are secondary. Variant II for retail buildings and offices with greater visibility.
Critical installation aspects
- Factory-trimmed panel edge (item 01) — requires ordering the panel with the “eaves edge” option on the spec sheet. Non-standard = production lead time longer by 2-3 weeks.
- OB-26 Z-flashing — Z-shaped geometry fastened to the roof panel + shielding the gutter inlet. Transverse joints of OB-26 (between linear metres) sealed with butyl compound (item 14) — unsealed joints will leak.
- OB-27 snow guard — installed 20-30 cm above the gutter, every 3-4 linear metres in the wind exposure zone. Mandatory for buildings >12 m in height.
- Gutter — design according to drainage area (typically Ø150 mm for 100 m² of roof slope).
- Roof edge zone — self-drilling fasteners at double density (item 09, 6 pcs/m² instead of 3 in the interior zone) — protection against wind suction forces.
Featured in the insPIRe® D multi-span pitched roof system.
Documentation
Gór-Stal Technical Catalogue 2025, p. 99 — cross-section along the slope with gutter.
Components in this junction
Panel (2)
- 01
- 03 insPIRe® U wall panel (insPIRe U)
Flashing (3)
- 04 OB-26 sub-gutter Z-flashing (OB-26)
- 05 OB-27 snow guard (OB-27)
- 06 OB-02 corner flashing (OB-02)
Accessory (1)
- 10 PM1 mounting washer (PM1)
Fastener (3)
- 09 Self-drilling fastener for sandwich panels
- 11 Sheet metal fastener (hex head)
- 12 Sheet metal fastener (washer head)
Sealant (3)
- 07 Self-adhesive PES sealing tape
- 08 Polyurethane assembly foam
- 14 Butyl sealing compound
Element (2)
- 02 Building structure as per design
- 13 PVC/metal gutter