Base · GS MW

Floor-level installation — horizontal layout of GS MW S/CH panels

Bottom fixing of horizontally-laid GS MW sandwich panels at the concrete floor slab. No sill beam (economy variant). OB-06 corner flashing finishes the bottom edge, mineral wool fills the space at the load-bearing column.

Floor-level installation — horizontal layout of GS MW S/CH panels

Junction function

Fixing horizontal panels to the floor slab = alternative to a plinth with sill beam (p. 27-30). Used when:

  • Hall with floor at ground level — no protruding sill beam.
  • Budget construction — without costly OB-14/15 plinth flashing.
  • Hall inside a larger enclosure — e.g. an internal warehouse within a main hall.

Construction is simpler than at the plinth — no OB-13/14/15 drip flashing, no OB-42 channel profile. Just:

  1. Concrete floor slab (at the internal hall floor level).
  2. Structural columns (item 02) in steel.
  3. Horizontal panels (item 01) rest with their bottom edge on the slab with a PES gasket (item 05).
  4. OB-06 corner flashing (item 03) finishes the bottom edge from the inside.

Critical installation aspects

  • Direct panel-to-slab contact = risk of capillary moisture rise into the mineral wool insulation layer; requires slab waterproofing (5 mm SBS bituminous membrane) extending under the panel with a 10 cm overlap.
  • Mineral wool (item 06) in the space between panel and structural column — eliminates the thermal bridge at the column.
  • Expansion anchors (item 09) fixing the bottom flashing to the slab — every 60 cm in the middle zone, every 40 cm in the edge zone.
  • OB-06 corner flashing mounted inside the hall; the external side has only the panel-to-slab contact + silicone sealant.
  • Not recommended for uncovered halls — without a drip flashing, rainwater is directed “into the hall” instead of “away from the hall”; only for internal halls within a larger enclosure or where the slab is raised at least 15 cm above the surrounding terrain.

Documentation

GS MW S/CH/U Technical Catalogue (Gór-Stal 2025), page 27 — Installation at the floor slab, horizontal layout. Scale 1:5.

Components in this junction

Panel (1)
Insulation (1)
  • 06
    Rock mineral wool infill
Flashing (2)
Fastener (3)
  • 07
    Self-drilling fastener for sandwich panels
  • 08
    Self-drilling fastener for sheet metal or 4.0×8.0 rivet
  • 09
    Steel expansion anchor, quick-fix type
Sealant (1)
  • 05
    PES sealing tape
Element (1)
  • 02
    Steel column per structural design