Junction function
Floor mounting = alternative to a base course with a sill beam. Used for interior halls or floor slabs raised >15 cm above ground level.
Critical installation aspects
- OB-42 channel raised 30 mm above the floor (waterproofing).
- Expansion anchors at 60 cm centres in the field zone, 40 cm at the edge zone.
- No OB-13 drip flashing — only for interior halls inside a larger enclosure.
- PIR vs MW — no mineral wool inside the channel (PIR is rigid and self-supporting).
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 14 — Floor mounting, vertical S layout. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (2)
- 02 OB-42 starter channel (OB-42)
- 03 OB-05 cover trim (OB-05)
Fastener (3)
- 05 Self-drilling fastener for sandwich panels
- 06 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
- 07 Steel quick-install expansion anchor
Sealant (1)
- 04 Impregnated PURS gasket or expanding foam