Junction function
insPIRe® S lock 60-120 mm = standard thickness range for typical industrial hall façades. Each thickness gives a different U-value:
| Thickness | U [W/m²K] | Typical use |
|---|---|---|
| 60 mm | 0.36 | unheated / lightly heated storage halls |
| 80 mm | 0.27 | standard heated halls |
| 100 mm | 0.22 | WT 2021 for heated walls |
| 120 mm | 0.18 | halls with increased requirements (passive) |
Identical lock geometry for all thicknesses — allows mixing thicknesses on a single façade (e.g. ground floor 100 mm + upper floor 80 mm) without additional flashings.
Critical installation aspects
- Gap between panels min. 1 mm for thermal movement.
- PUS gasket factory-pressed — ready to use, no additional work required.
- Air tightness class 1 per PN-EN 14509.
- Installation sequence from bottom to top / from the end support.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 11 — Lock and joint of S panels 60/80/100/120 mm. Scale 1:5.
Components in this junction
Panel (1)
- GS insPIRe® S wall panel 60/80/100/120 mm (insPIRe S)
Sealant (1)
- PUS gasket 6 mm thick, factory-fitted