Detail · insPIRe®

Fixing of insPIRe® S panels 60-120 mm thick — section A-A and B-B

Standard fixing of insPIRe® S sandwich panels 60-120 mm thick to steel purlin. Self-drilling fasteners in the centre of the joint, minimum 3 pieces per 1000 mm width. PES sealing tape at panel-purlin interface.

Fixing of insPIRe® S panels 60-120 mm thick — section A-A and B-B

Junction function

Standard fixing of insPIRe® S 60-120 mm = the basis of all typical industrial hall facades. Longer fastener than in S 40, higher structural load capacity, allowing wider purlin spacing.

Critical installation aspects

  • Min. 3 fasteners per 1000 mm width = purlin spacing typically 3.0-4.5 m.
  • Tightening torque 8-12 Nm (torque-controlled screwdriver).
  • Driving pattern = centre of the joint; deviation >5 mm damages the joint.
  • Edge zone (3 m from the corner) = 4 fasteners / width.
  • Fastener inspection after 12 months in industrial halls subject to vibration.

Documentation

Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 11 — Fixing of S panels 60-120 mm thick. Scale 1:5.

Components in this junction

Panel (1)
Fastener (1)
  • 02
    Self-drilling fastener for sandwich panel fixing
Sealant (1)
  • 04
    PES sealing tape
Element (1)
  • 03
    Purlin as per structural design