Junction function
Variant III of horizontal U plinth = with two-part OB-15+OB-15a drip flashing. Third aesthetic option.
Critical installation aspects
- OB-15a stiffener anchored first with expansion anchors.
- OB-15 drip flashing bonded onto the stiffener.
- Joints sealed with neutral silicone.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 64 — Plinth, horizontal U layout, variant III. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® U wall panel (insPIRe U)
Flashing (2)
- 03 OB-15 drip flashing (OB-15)
- 04 OB-15a stiffening flashing (OB-15a)
Accessory (1)
- 08 PM1 mounting washer (PM1)
Fastener (3)
- 07 Self-drilling fastener for sandwich panels
- 09 Steel quick-mount expansion anchor
- 10 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
Sealant (3)
- 05 PES sealing tape
- 06 Impregnated PURS gasket or installation foam
- 11 Neutral silicone sealant
Element (1)
- 02 Structural elements + insulation