Junction function
Horizontal insPIRe® S plinth = analogous to MiWo S/CH (page 27). Key principles are identical.
Critical installation aspects
- OB-38 Z-profile anchored with expansion bolts to the sill beam.
- OB-14 drip flashing projects 60-100 mm + 30 mm drip edge.
- OB-06 internal corner at the bottom.
- PURS foam beneath the panel instead of mineral wool.
Documentation
Technical Catalogue insPIRe S/U + GS PIR D (Gór-Stal 2025), page 26 — Plinth, horizontal S arrangement, variant I. Scale 1:5.
Components in this junction
Panel (1)
- 01 GS insPIRe® S wall panel (insPIRe S)
Flashing (4)
- 03 OB-38 starter Z-profile (OB-38)
- 04 OB-14 drip flashing (OB-14)
- 05 Trim flashing covering panel joints
- 06 OB-06 corner flashing (OB-06)
Fastener (4)
- 09 Self-drilling fastener for sandwich panels
- 10 Steel quick-mount expansion anchor
- 11 Self-drilling fastener for sheet metal or 4.0×8.0 rivet
- 12 4.0×8.0 rivet
Sealant (2)
- 07 PES sealing tape
- 08 Impregnated PURS gasket or assembly foam
Element (1)
- 02 Structural elements + insulation