Junction function
Junction of a GS PIR D sandwich panel roof with a reinforced concrete or masonry wall along the slope — a typical detail for halls with a full-height RC parapet preventing fire spread between segments.
Unlike a classic parapet (where the parapet is part of the panel structure), here the RC wall is an independent structure — it extends above the roof or runs parallel to the roof edge.
The set of four flashings (OB-28, OB-30, OB-12, OB-07) creates a three-layer seal:
- OB-30 slope flashing (item 06) — horizontal flashing on the panel on the wall side.
- OB-28 profiled flashing (item 05) — vertical flashing fixed to the wall.
- OB-12 drip flashing (item 07) — lower water-draining element.
- OB-07 internal corner (item 08) — closes the angle between the wall and the roof plane.
Critical installation aspects
- OB-30 + PES gasket (items 06, 09) on the surface of the roof panel. Strip min. 200 mm wide.
- OB-28 (item 05) fixed to the RC wall with expansion anchors (item 14) every 250 mm. It does NOT touch the roof plane — a ~10 mm gap is filled with butyl (item 11).
- PU foam (item 10) fills the gap between OB-28 and the roof plane — low-expansion type, expansion ≤ 30%.
- OB-12 drip flashing (item 07) at the bottom — bent with a 30 mm drip edge, fixed to OB-30.
- OB-07 internal corner (item 08) — connects OB-30 with OB-28 at the corner, with a 100 mm overlap under both.
- Sandwich panel fasteners (item 12) at double density in a 50 cm strip from the wall — wind suction forces at the lateral roof edge are higher.
Classic parapet vs RC wall
| Aspect | Panel parapet (classic) | RC wall (this junction) |
|---|---|---|
| Material | GS PIR panel / insulation | reinforced concrete |
| Height above roof | 30-150 cm | 100-500 cm (full height) |
| Fire function | none | typically class EI 120 |
| Number of flashings | OB-28+OB-12 (2) | OB-28+OB-30+OB-12+OB-07 (4) |
| Price per lm | base | +200% (RC structure) |
| Application | typical halls | halls requiring fire separation between segments |
Used in the pitched roof GS PIR D — multi-span system.
Documentation
Gór-Stal Technical Catalogue 2025, p. 101 — GS PIR D roof junction with RC wall, cross-section along the slope.
Components in this junction
- 01 GS PIR D roof panel (GS PIR D)
- 05 Profiled flashing OB-28 (OB-28)
- 06 Roof slope flashing OB-30 (OB-30)
- 07 Drip flashing OB-12 (OB-12)
- 08 Internal corner flashing OB-07 (OB-07)
- 12 Self-drilling fastener for sandwich panels
- 13 Hex-head fastener
- 14 Quick-mount steel expansion anchor
- 15 Washer-head fastener
- 04 Profiled gasket (PE)
- 09 Self-adhesive PES sealing tape
- 10 Polyurethane assembly foam
- 11 Butyl sealant
- 02 Purlin per structural design
- 03 Reinforced concrete or masonry fire wall