Wall · termPIR®

ETICS External Wall — termPIR® ETX

Two-layer light-wet system with vapour-permeable termPIR® ETX board (glass veil). Meets WT 2021 requirements for external walls at a thickness 30–40% lower than EPS or mineral wool.

λD
0,027 W/(m·K)
U [W/m²·K]
0,19–0,49
Fire reaction
E (50–250 mm)
ETICS External Wall — termPIR® ETX

When to use this system

The two-layer light-wet ETICS system with termPIR® ETX is used when:

  • A thin wall is a priority — e.g. plot constraints, building boundaries, refurbishments where a thicker insulation will not fit with existing window joinery.
  • Wall vapour permeability is desired (μ = 90–170) — important for external walls above damp rooms and in renovations of heritage buildings.
  • Biological durability and water resistance are required — PIR is resistant to rodents, fungi, mould and condensation (water absorption < 2%).

At a thickness of 120 mm termPIR® ETX we achieve U = 0.20 W/m²·K — exactly the WT 2021 requirement for external walls in heated rooms. For comparison, the same U value requires ~210 mm of mineral wool (λ = 0.040) or ~190 mm of EPS (λ = 0.038).

Installation requirements

Key rules arising from the technology and the European Technical Assessment ETA-17/0066:

  • Seasoning — ETX boards should be installed no earlier than 1 month after the production date (allowing dimensions to stabilise).
  • Bonding — universal adhesive should cover at least 80% of the board surface (the perimeter-and-dot method is not recommended).
  • Mechanical fasteners — disc anchors with PIR or EPS caps, 62 mm in diameter:
    • min. 4 pcs/m² up to a building height of 12 m
    • min. 6 pcs/m² in edge zones (corners, around openings, roof edges)
    • anchor length matched to board thickness + substrate layer + ≥35 mm embedment in the load-bearing wall
  • PIR caps cover the anchor discs after fastening — this eliminates thermal bridges and the “ladybird” effect (visible patches on the façade around anchors).
  • Reinforcing mesh made of glass fibre (≥160 g/m²) embedded in a 3 mm adhesive layer — overlap of at least 10 cm between strips.
  • Thin-coat render applied after full drying of the reinforced layer (min. 7 days).

Edge profiling and thickness calibration

termPIR® ETX is available with a straight edge profile in 600 × 1200 mm format. Thickness calibration of ±0.5 mm ensures evenness of the insulation face without sanding.

  • termPIR® ETX — default choice for ETICS systems. Double-sided glass veil, λD 0.025–0.027 W/(m·K) depending on thickness.
  • termPIR® ETX R-eco — variant with recycled content (>10% secondary raw material), required for public procurement covered by CAM criteria and for LEED and BREEAM certification.

Installation components from the BOKKA offer

In addition to termPIR® boards, an ETICS system requires the standard components (adhesive, anchors, mesh, render) available from the system manufacturer (e.g. Atlas, Bolix, Caparol, Knauf). Directly from our offer:

  • PIR caps Ø 62 mm — eliminate thermal bridges at mechanical fasteners
  • PES expansion tape — for window and door joinery

Note: this system does not use the flashings from our catalogue (OB-XX codes apply to sandwich panel systems).

Technical documentation

The system is described in the termPIR® Technical Catalogue — Residential Buildings (Gór-Stal, 2022-04-26, pp. 33–39). It holds the European Technical Assessment ETA-17/0066 issued by ITB and approval for use in ETICS systems on the EU market.

Layer composition

# Layer Thickness λ Role
1 Load-bearing wall (concrete, brick, aerated concrete) load-bearing structure
2 Cement-lime plaster (substrate) substrate levelling
3 Universal adhesive board bonding (≥80% surface)
4 termPIR® ETX 50–130 mm 0,027 W/(m·K) main vapour-permeable insulation
5 Mechanical fastener with cap (anchor) fixing ≥4 pcs/m², ≥6 in edge zones
6 Universal adhesive + glass-fibre mesh 3 mm reinforced layer
7 Bonding / polysilicate primer render undercoat
8 Thin-coat render (silicone / acrylic / mineral-polymer) external finish

U-value by insulation thickness

termPIR® thickness U [W/m²·K] Meets WT 2021 (roof U ≤ 0.15)
50 mm 0,49 — no
60 mm 0,42 — no
70 mm 0,36 — no
80 mm 0,31 — no
90 mm 0,28 — no
100 mm 0,25 — no
110 mm 0,23 — no
120 mm 0,20 — no
130 mm 0,19 — no

Related catalogue items

0

Structural junctions for this system

Mounting details from manufacturer catalogues — ridge, parapet, plinth, openings, junctions.

All junctions →